Higher doses of loop diuretics limit uptitration of angiotensin-converting enzyme inhibitors in patients with heart failure and reduced ejection fraction.

Department of Cardiology, University Medical Centre Groningen, University of Groningen, Hanzeplein 1, 9713 GZ, Groningen, The Netherlands. Ziekenhuis Oost-Limburg, Genk, Belgium. University of Bergen, Bergen, Norway. Stavanger University Hospital, Stavanger, Norway. Department of Heart Diseases, Poland and Cardiology Department, Military Hospital, Wroclaw Medical University, Wrocław, Poland. Division of Molecular and Clinical Medicine, School of Medicine, Ninewells Hospital and Medical School, University of Dundee, Dundee, UK. Department of Cardiovascular Sciences, University of Leicester, Leicester, UK. NIHR Leicester Biomedical Research Centre, Glenfield Hospital, Leicester, LE3 9QP, UK. Department of Cardiology (CVK), and Berlin-Brandenburg Center for Regenerative Therapies (BCRT), German Centre for Cardiovascular Research (DZHK) Partner Site Berlin, Charité Universitätsmedizin Berlin, Berlin, Germany. Department of Cardiology and Pneumology, University Medical Center Göttingen (UMG), Göttingen, Germany. Heart Failure Unit, Department of Cardiology, School of Medicine, Athens University Hospital Attikon, National and Kapodistrian University of Athens, Athens, Greece. School of Medicine, University of Cyprus, Nicosia, Cyprus. National Heart and Lung Institute, Royal Brompton and Harefield Hospitals, Imperial College, London, UK. INSERM, Centre D'Investigations Cliniques Plurithématique 1433, Université de Lorraine, CHRU de Nancy and F-CRIN INI-CRCT, Nancy, France. Department of Medical and Surgical Specialties, Radiological Sciences and Public Health, Institute of Cardiology, University of Brescia, Brescia, Italy. Department of Cardiology, University Medical Centre Groningen, University of Groningen, Hanzeplein 1, 9713 GZ, Groningen, The Netherlands. a.a.voors@umcg.nl.

Clinical research in cardiology : official journal of the German Cardiac Society. 2020;(8):1048-1059

Abstract

BACKGROUND Loop diuretics are frequently prescribed to patients with heart failure and reduced ejection fraction (HFrEF) for the treatment of congestion; however, they might hamper uptitration of inhibitors of the renin-angiotensin system. METHODS Loop diuretic dose at baseline was recorded in 2338 patients with HFrEF enrolled in BIOSTAT-CHF, an international study of HF patients on loop diuretic therapy who were eligible for uptitration of angiotensin-converting enzyme inhibitors (ACEi)/mineralocorticoid receptor antagonists (MRA). The association between loop diuretic dose and uptitration of ACEi/MRA to percentage of target dose was adjusted for a previously published model for likelihood of uptitration and a propensity score. RESULTS Baseline median loop diuretic dose was 40 [40-100] mg of furosemide or equivalent. Higher doses of loop diuretics were associated with higher NYHA class and higher levels of NT-proBNP, more severe signs and symptoms of congestion, more frequent MRA use, and lower doses of ACEi reached at 3 and 9 months (all P < 0.01). After propensity adjustment, higher doses of loop diuretics remained significantly associated with poorer uptitration of ACEi (Beta per log doubling of loop diuretic dose: - 1.66, P = 0.021), but not with uptitration of MRAs (P = 0.758). Higher doses of loop diuretics were independently associated with an increased risk of all-cause mortality or HF hospitalization [HR per doubling of loop diuretic dose: 1.06 (1.01-1.12), P = 0.021]. CONCLUSIONS Higher doses of loop diuretics limited uptitration of ACEi in patients with HFrEF and were associated with a higher risk of death and/or HF hospitalization, independent of their lower likelihood of uptitration and higher baseline risk. This figure was created with images adapted from Servier Medical Art licensed under a Creative Commons Attribution 3.0.

Methodological quality

Publication Type : Multicenter Study ; Observational Study

Metadata